Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Bombas Ideal Fire Pump

Bombas Ideal Fire Fighting Packages

As a fire-extinguishing agent, water acts by cooling the source of combustion, and can be applied by various methods to ob tain the greatest degree of heat removal. Systems such as sprinklers, water curtains, hydration columns, fire hydrants, etc. all require a water supply permanently available from a pressurized network.

In the event of a fire, either the opening of a fire hydrant or the automatic initiation of a fixed sprinklers installation usually initiates the demand for water. The sudden fall in pressure in the fire system rising main causes the main pumps to automatically start and provide the required flow of water to the points of application. Most systems have a small, electrically driven auxiliary or jockey pump, which automatically maintains the pressurization of the fire fighting system and compensates for small leakages in the system. The auxiliary or jockey pump operates automatically under pressure switch control.

The main pumps are designed to provide the supply of pressurized water to the Fire Fighting System; these can be initiated either manually or automatically as required. A sudden drop in pressure causes the automatic starting of the main pumps to supply water to the fire system rising main. The main fire pumps may only be stopped manually.

bombas ideal fire pump nfpa 20

The types of pump used for this application are mainly:
1. Horizontal end suction pump with a radial discharge.
2. Horizontal axially split case pumps.
3. Vertical, wet well pumps-shaft driven with conventional motors.

By manufacturing a wide range of pumps, BOMBAS IDEAL is able to impartially recommend the most appropriate design of pumping equipment for a given application. For example, we would typically recommend horizontally mounted pumps for installations, which have a positive suction head, and when a suction lift is required (i.e. when the source of the water supply is located below pumping equipment), we would suggest vertical wet well pumps IDEAL FIRE-FIGHTING EQUIPMENT is manufactured according to the requirements of UNE-23 500-90, CEPREVEN RT, 2ABA standards. Optionally, the equipment can be built to comply with other Standards such as NFPA-20, etc.